Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*", "matchCriteriaId": "9BB1DC91-D673-4755-AD47-1E46B6446D1D", "versionEndIncluding": "5.4", "vulnerable": true}, {"criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "32F0E13C-4862-4A58-8F16-4E0D925FEA33", "versionEndIncluding": "1.606g", "vulnerable": true}, {"criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "89ACB781-BD3B-4BA2-B036-D6D95FB3AC05", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker."}, {"lang": "es", "value": "Una vulnerabilidad de desbordamiento de enteros en las versiones 1.606G y anteriores de Mitsubishi Electric GX Works2, en las versiones 2.84N y anteriores de Mitsubishi Electric MELSOFT Navigator y en las versiones 5.4 y anteriores de Mitsubishi Electric EZSocket permite que un atacante provoque una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en el software haciendo que un usuario abra un archivo de proyecto malicioso especialmente dise\u00f1ado por un atacante"}], "id": "CVE-2021-20607", "lastModified": "2024-11-21T05:46:51.930", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0"}, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2021-12-17T17:15:11.890", "references": [{"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": ["Patch", "Third Party Advisory"], "url": "https://jvn.jp/vu/JVNVU93817405/index.html"}, {"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-350-05"}, {"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": ["Patch", "Vendor Advisory"], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-021_en.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Patch", "Third Party Advisory"], "url": "https://jvn.jp/vu/JVNVU93817405/index.html"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-350-05"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Patch", "Vendor Advisory"], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-021_en.pdf"}], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-191"}], "source": "nvd@nist.gov", "type": "Primary"}]}