Show plain JSON{"containers": {"cna": {"affected": [{"product": "Software House C\u2022CURE 9000 v2.70", "vendor": "Johnson Controls", "versions": [{"status": "affected", "version": "2.70"}]}, {"product": "American Dynamics victor Video Management System v5.2", "vendor": "Johnson Controls", "versions": [{"status": "affected", "version": "5.2"}]}], "descriptions": [{"lang": "en", "value": "During installation or upgrade to Software House C\u2022CURE 9000 v2.70 and American Dynamics victor Video Management System v5.2, the credentials of the user used to perform the installation or upgrade are logged in a file. The install log file persists after the installation."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}}], "problemTypes": [{"descriptions": [{"cweId": "CWE-312", "description": "CWE-312 - Cleartext Storage of Sensitive Information", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2020-05-21T14:45:44", "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01", "shortName": "jci"}, "references": [{"tags": ["x_refsource_CONFIRM"], "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"}, {"name": "ICS-CERT Advisory", "tags": ["third-party-advisory", "x_refsource_CERT"], "url": "https://www.us-cert.gov/ics/advisories/ICSA-20-142-01"}], "solutions": [{"lang": "en", "value": "All users should upgrade to the latest version. \n\nPlease note that while the upgrade will automatically remove the log file, we recommend existing deployments to securely delete the log file from the following path c:\\ProgramData\\Tyco\\InstallerTemp and then change the password for the affected user account. "}], "source": {"discovery": "EXTERNAL"}, "title": "C\u2022CURE 9000 and victor Video Management System - Cleartext storage of user credentials upon installation or upgrade of software.", "x_generator": {"engine": "Vulnogram 0.0.9"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "productsecurity@jci.com", "ID": "CVE-2020-9045", "STATE": "PUBLIC", "TITLE": "C\u2022CURE 9000 and victor Video Management System - Cleartext storage of user credentials upon installation or upgrade of software."}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "Software House C\u2022CURE 9000 v2.70", "version": {"version_data": [{"version_affected": "=", "version_value": "2.70"}]}}, {"product_name": "American Dynamics victor Video Management System v5.2", "version": {"version_data": [{"version_affected": "=", "version_value": "5.2"}]}}]}, "vendor_name": "Johnson Controls"}]}}, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "During installation or upgrade to Software House C\u2022CURE 9000 v2.70 and American Dynamics victor Video Management System v5.2, the credentials of the user used to perform the installation or upgrade are logged in a file. The install log file persists after the installation."}]}, "generator": {"engine": "Vulnogram 0.0.9"}, "impact": {"cvss": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-312 - Cleartext Storage of Sensitive Information"}]}]}, "references": {"reference_data": [{"name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories", "refsource": "CONFIRM", "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"}, {"name": "ICS-CERT Advisory", "refsource": "CERT", "url": "https://www.us-cert.gov/ics/advisories/ICSA-20-142-01"}]}, "solution": [{"lang": "en", "value": "All users should upgrade to the latest version. \n\nPlease note that while the upgrade will automatically remove the log file, we recommend existing deployments to securely delete the log file from the following path c:\\ProgramData\\Tyco\\InstallerTemp and then change the password for the affected user account. "}], "source": {"discovery": "EXTERNAL"}}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-04T10:19:19.232Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"}, {"name": "ICS-CERT Advisory", "tags": ["third-party-advisory", "x_refsource_CERT", "x_transferred"], "url": "https://www.us-cert.gov/ics/advisories/ICSA-20-142-01"}]}]}, "cveMetadata": {"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01", "assignerShortName": "jci", "cveId": "CVE-2020-9045", "datePublished": "2020-05-21T14:45:44", "dateReserved": "2020-02-18T00:00:00", "dateUpdated": "2024-08-04T10:19:19.232Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}