Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "5CBE98E7-30D6-422E-8FF2-5EFEEA473CDF", "versionEndIncluding": "14.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:schneider-electric:unity_pro:*:*:*:*:*:*:*:*", "matchCriteriaId": "51476F6C-7515-4DD4-8D3D-5E86C1EEFC06", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "076769A2-52DE-4B81-A714-41B3F806B9C9", "versionEndExcluding": "3.20", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*", "matchCriteriaId": "138681A2-0146-492B-8E10-06849FC27C6E", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03B4D2FF-B0A3-4879-B006-2F64D93DB173", "versionEndExcluding": "3.10", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*", "matchCriteriaId": "E876C738-ABF6-4864-98A6-1E06E96A0DF4", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller."}, {"lang": "es", "value": "Una CWE-74: Una Neutralizaci\u00f3n Inapropiada de Elementos Especiales en la Salida Usada por un Componente Aguas Abajo (\"Inyection\"), una DLL reflexiva, la vulnerabilidad se presenta en EcoStruxure Control Expert (todas las versiones anteriores a 14.1 Hot Fix), Unity Pro (todas las versiones), Modicon M340 (todas las versiones anteriores a V3.20), Modicon M580 (todas las versiones anteriores a V3.10), que, si es explotada, podr\u00eda permitir a atacantes transferir c\u00f3digos maliciosos hacia el controlador."}], "id": "CVE-2020-7475", "lastModified": "2024-11-21T05:37:13.210", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2020-03-23T19:15:12.413", "references": [{"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "http://www.se.com/ww/en/download/document/SEVD-2020-080-01"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-74"}], "source": "cybersecurity@se.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-74"}], "source": "nvd@nist.gov", "type": "Primary"}]}