Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:dell:encryption:*:*:*:*:*:enterprise:*:*", "matchCriteriaId": "1AED63E2-8120-40F9-A877-4C99F8961503", "versionEndIncluding": "10.7.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:dell:endpoint_security_suite_enterprise:*:*:*:*:*:*:*:*", "matchCriteriaId": "8D1B24E0-082E-4131-8C12-65A85190AF76", "versionEndExcluding": "2.7", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "Dell Encryption versions prior to 10.7 and Dell Endpoint Security Suite versions prior to 2.7 contain a privilege escalation vulnerability due to incorrect permissions. A local malicious user with low privileges could potentially exploit this vulnerability to gain elevated privilege on the affected system with the help of a symbolic link."}, {"lang": "es", "value": "Dell Encryption versiones anteriores a 10.7 y Dell Endpoint Security Suite versiones anteriores a 2.7, contienen una vulnerabilidad de escalada de privilegios debido a permisos incorrectos. Un usuario malicioso local con pocos privilegios podr\u00eda explotar esta vulnerabilidad para alcanzar privilegios elevados en el sistema afectado con la ayuda de un enlace simb\u00f3lico"}], "id": "CVE-2020-5358", "lastModified": "2024-11-21T05:33:58.590", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "security_alert@emc.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2020-06-15T21:15:10.820", "references": [{"source": "security_alert@emc.com", "tags": ["Vendor Advisory"], "url": "https://www.dell.com/support/article/SLN321789"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.dell.com/support/article/SLN321789"}], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-732"}], "source": "security_alert@emc.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-732"}], "source": "nvd@nist.gov", "type": "Primary"}]}