Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61EDDB16-D51C-440B-AEB5-3F087BC5E5A0", "versionEndIncluding": "4.32.10.00", "vulnerable": true}, {"criteria": "cpe:2.3:o:dell:idrac9_firmware:4.40.00.00:*:*:*:*:*:*:*", "matchCriteriaId": "F478B785-B01A-4715-A2E0-ED239299BDE0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link."}, {"lang": "es", "value": "Dell EMC iDRAC9 versiones anteriores a 4.32.10.00 y 4.40.00.00, contienen una vulnerabilidad de tipo cross-site scripting reflejada en la aplicaci\u00f3n web de iDRAC9. Un atacante remoto podr\u00eda potencialmente explotar esta vulnerabilidad para ejecutar HTML o JavaScript maliciosos en el navegador de una v\u00edctima enga\u00f1\u00e1ndola para que siga un enlace especialmente dise\u00f1ado"}], "id": "CVE-2020-26198", "lastModified": "2024-11-21T05:19:30.567", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0"}, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0"}, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "security_alert@emc.com", "type": "Secondary"}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2020-12-16T16:15:13.883", "references": [{"source": "security_alert@emc.com", "tags": ["Vendor Advisory"], "url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"}], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-79"}], "source": "security_alert@emc.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-79"}], "source": "nvd@nist.gov", "type": "Primary"}]}