Show plain JSON{"containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "Clinical Collaboration Platform", "vendor": "Philips", "versions": [{"lessThan": "12.2.1", "status": "affected", "version": "0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "value": "Northridge Hospital Medical Center reported these vulnerabilities to Philips."}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "<p>Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, \n\ndoes not properly control the allocation and maintenance of a limited \nresource, thereby enabling an attacker to influence the amount of \nresources consumed, eventually leading to the exhaustion of available \nresources.\n\n</p>"}], "value": "Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, \n\ndoes not properly control the allocation and maintenance of a limited \nresource, thereby enabling an attacker to influence the amount of \nresources consumed, eventually leading to the exhaustion of available \nresources."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-757", "description": "CWE-757", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2025-06-04T21:21:08.344Z"}, "references": [{"tags": ["x_refsource_MISC"], "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"}, {"url": "https://www.philips.com/a-w/security/security-advisories/product-security-2020.html#2020_archive"}], "solutions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "<p></p><p>Philips \nrequires manual intervention to remediate CVE-2020-16200.</p>\n\n<p></p><p>Users with questions regarding their specific Philips Clinical \nCollaboration Platform installations and new release eligibility should \ncontact <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.usa.philips.com/healthcare/solutions/customer-service-solutions\">Philips service support, or regional service support</a>, or call 1-877-328-2808, option 4.</p><p>The Philips advisory and the latest security information for Philips products are available at the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/productsecurity\">Philips product security website</a>.\n\n<br></p>"}], "value": "Philips \nrequires manual intervention to remediate CVE-2020-16200.\n\n\n\n\n\nUsers with questions regarding their specific Philips Clinical \nCollaboration Platform installations and new release eligibility should \ncontact Philips service support, or regional service support https://www.usa.philips.com/healthcare/solutions/customer-service-solutions , or call 1-877-328-2808, option 4.\n\nThe Philips advisory and the latest security information for Philips products are available at the Philips product security website https://www.philips.com/productsecurity ."}], "source": {"advisory": "ICSMA-20-261-01", "discovery": "EXTERNAL"}, "title": "Philips Clinical Collaboration Platform Algorithm Downgrade", "x_generator": {"engine": "Vulnogram 0.2.0"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-14506", "STATE": "PUBLIC"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "Philips Clinical Collaboration Platform", "version": {"version_data": [{"version_value": "Versions 12.2.1 and prior"}]}}]}, "vendor_name": "n/a"}]}}, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CROSS-SITE REQUEST FORGERY (CSRF) CWE-352"}]}]}, "references": {"reference_data": [{"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"}]}}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-04T13:37:54.144Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_MISC", "x_transferred"], "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"}]}]}, "cveMetadata": {"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-16200", "datePublished": "2020-09-18T17:53:23", "dateReserved": "2020-07-31T00:00:00", "dateUpdated": "2025-06-04T21:21:08.344Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}