Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*", "matchCriteriaId": "555D034F-3D64-4ED1-9B63-F8D59199E99C", "versionEndExcluding": "1.2.2.3", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208."}, {"lang": "es", "value": "UltraVNC, en su revisi\u00f3n 1207, tiene m\u00faltiples vulnerabilidades de acceso fuera de l\u00edmites conectadas al uso incorrecto de la funci\u00f3n ClientConnection::Copybuffer en el c\u00f3digo VNC del cliente, lo que podr\u00eda resultar en una ejecuci\u00f3n de c\u00f3digo. Este ataque parece ser explotable mediante la conectividad de red. Se requiere la interacci\u00f3n del usuario para desencadenar estas vulnerabilidades. Se han solucionado estas vulnerabilidades en la revisi\u00f3n 1208."}], "id": "CVE-2019-8266", "lastModified": "2024-11-21T04:49:36.597", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2019-03-08T23:29:00.547", "references": [{"source": "vulnerability@kaspersky.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"}, {"source": "vulnerability@kaspersky.com", "tags": ["Third Party Advisory"], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/"}, {"source": "vulnerability@kaspersky.com", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory"], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"}], "sourceIdentifier": "vulnerability@kaspersky.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-788"}], "source": "vulnerability@kaspersky.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-125"}, {"lang": "en", "value": "CWE-787"}], "source": "nvd@nist.gov", "type": "Primary"}]}