Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AECF5778-C5F5-4789-BD3D-793B35DDDBDF", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*", "matchCriteriaId": "60D9A366-3394-4275-B884-AE6E7227156E", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol."}, {"lang": "es", "value": "CWE-284: Existe una vulnerabilidad de Control de Acceso Inapropiada en el m\u00f3dulo BMXNOR0200H Ethernet/Serial RTU (todas las versiones de firmware), lo que podr\u00eda causar la ejecuci\u00f3n de comandos por parte de usuarios no autorizados al utilizar el protocolo IEC 60870-5-104."}], "id": "CVE-2019-6810", "lastModified": "2024-11-21T04:47:12.243", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2019-09-17T20:15:11.860", "references": [{"source": "cybersecurity@se.com", "tags": ["Third Party Advisory"], "url": "https://security.cse.iitk.ac.in/responsible-disclosure"}, {"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory"], "url": "https://security.cse.iitk.ac.in/responsible-disclosure"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-284"}], "source": "cybersecurity@se.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "NVD-CWE-Other"}], "source": "nvd@nist.gov", "type": "Primary"}]}