Show plain JSON{"containers": {"cna": {"affected": [{"product": "iDRAC", "vendor": "Dell EMC", "versions": [{"lessThan": "2.92", "status": "affected", "version": "2.92", "versionType": "custom"}, {"lessThan": "2.61.60.60", "status": "affected", "version": "2.61.60.60", "versionType": "custom"}, {"lessThan": "3.20.21.20", "status": "affected", "version": "3.20.21.20", "versionType": "custom"}, {"lessThan": "3.21.24.22", "status": "affected", "version": "3.21.24.22", "versionType": "custom"}, {"lessThan": "3.23.23.23", "status": "affected", "version": "3.23.23.23", "versionType": "custom"}, {"lessThan": "3.21.26.22", "status": "affected", "version": "3.21.26.22", "versionType": "custom"}]}], "datePublic": "2019-04-25T00:00:00", "descriptions": [{"lang": "en", "value": "Dell EMC iDRAC6 versions prior to 2.92, iDRAC7/iDRAC8 versions prior to 2.61.60.60, and iDRAC9 versions prior to 3.20.21.20, 3.21.24.22, 3.21.26.22 and 3.23.23.23 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to crash the webserver or execute arbitrary code on the system with privileges of the webserver by sending specially crafted input data to the affected system."}], "metrics": [{"cvssV3_0": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}}], "problemTypes": [{"descriptions": [{"cweId": "CWE-120", "description": "CWE-120 Buffer Overflow", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2019-04-26T18:22:08", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell"}, "references": [{"tags": ["x_refsource_MISC"], "url": "https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en"}], "source": {"discovery": "UNKNOWN"}, "title": "Buffer Overflow Vulnerability", "x_generator": {"engine": "Vulnogram 0.0.6"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "security_alert@emc.com", "DATE_PUBLIC": "2019-04-25T23:00:00.000Z", "ID": "CVE-2019-3705", "STATE": "PUBLIC", "TITLE": "Buffer Overflow Vulnerability"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "iDRAC", "version": {"version_data": [{"version_affected": "<", "version_name": "2.92", "version_value": "2.92"}, {"version_affected": "<", "version_name": "2.61.60.60", "version_value": "2.61.60.60"}, {"version_affected": "<", "version_name": "3.20.21.20", "version_value": "3.20.21.20"}, {"version_affected": "<", "version_name": "3.21.24.22", "version_value": "3.21.24.22"}, {"version_affected": "<", "version_name": "3.23.23.23", "version_value": "3.23.23.23"}, {"version_affected": "<", "version_name": "3.21.26.22", "version_value": "3.21.26.22"}]}}]}, "vendor_name": "Dell EMC"}]}}, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "Dell EMC iDRAC6 versions prior to 2.92, iDRAC7/iDRAC8 versions prior to 2.61.60.60, and iDRAC9 versions prior to 3.20.21.20, 3.21.24.22, 3.21.26.22 and 3.23.23.23 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to crash the webserver or execute arbitrary code on the system with privileges of the webserver by sending specially crafted input data to the affected system."}]}, "generator": {"engine": "Vulnogram 0.0.6"}, "impact": {"cvss": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-120 Buffer Overflow"}]}]}, "references": {"reference_data": [{"name": "https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en", "refsource": "MISC", "url": "https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en"}]}, "source": {"discovery": "UNKNOWN"}}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-04T19:19:17.425Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_MISC", "x_transferred"], "url": "https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en"}]}]}, "cveMetadata": {"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2019-3705", "datePublished": "2019-04-26T18:22:08.963679Z", "dateReserved": "2019-01-03T00:00:00", "dateUpdated": "2024-09-16T23:25:37.495Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}