Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:medtronic:valleylab_ft10_energy_platform_firmware:2.0.3:*:*:*:*:*:*:*", "matchCriteriaId": "89DAFB01-536A-4966-8EAC-5D6CED32CC63", "vulnerable": true}, {"criteria": "cpe:2.3:o:medtronic:valleylab_ft10_energy_platform_firmware:2.1.0:*:*:*:*:*:*:*", "matchCriteriaId": "31DF6D35-968D-4E8D-A8F5-578B4B9C2BE9", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:medtronic:valleylab_ft10_energy_platform:-:*:*:*:*:*:*:*", "matchCriteriaId": "164230CB-E2BF-447F-8537-C9401FA0CC09", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:medtronic:valleylab_ls10_energy_platform_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EEAE74E9-49AC-4B77-8831-11EA09B204CB", "versionEndIncluding": "1.20.2", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:medtronic:valleylab_ls10_energy_platform:-:*:*:*:*:*:*:*", "matchCriteriaId": "82294F1E-0BD0-4F55-A732-09B68AA37624", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN\u2014not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator."}, {"lang": "es", "value": "En Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) versi\u00f3n 2.1.0 y versiones anteriores y versi\u00f3n 2.0.3 y versiones atneriores, y Valleylab LS10 Energy Platform (VLLS10GEN \u2014no disponible en los Estados Unidos) versi\u00f3n 1.20.2 y versiones anteriores, se utiliz\u00f3 el mecanismo de seguridad RFID para la autenticaci\u00f3n entre la plataforma de energ\u00eda FT10 / LS10 y los instrumentos se pueden omitir, lo que permite que los instrumentos no aut\u00e9nticos se conecten al generador."}], "id": "CVE-2019-13531", "lastModified": "2024-11-21T04:25:05.343", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "LOW", "cvssData": {"accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0"}, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1"}, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2019-11-08T20:15:10.570", "references": [{"source": "ics-cert@hq.dhs.gov", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://www.us-cert.gov/ics/advisories/icsma-19-311-01"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://www.us-cert.gov/ics/advisories/icsma-19-311-01"}], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-287"}], "source": "ics-cert@hq.dhs.gov", "type": "Secondary"}, {"description": [{"lang": "en", "value": "NVD-CWE-noinfo"}], "source": "nvd@nist.gov", "type": "Primary"}]}