Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:intel:converged_security_and_management_engine:*:*:*:*:*:*:*:*", "matchCriteriaId": "1219056B-D42B-4D3A-9BBB-0EC6856D3E79", "versionEndExcluding": "12.0.35", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:intel:server_platform_services:*:*:*:*:*:*:*:*", "matchCriteriaId": "E4B4F480-DD79-4A66-9231-FDBE8342CAEA", "versionEndExcluding": "sps_e3_05.00.04.027.0", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "Insufficient access control vulnerability in subsystem for Intel(R) CSME before versions 11.x, 12.0.35 Intel(R) TXE 3.x, 4.x, Intel(R) Server Platform Services 3.x, 4.x, Intel(R) SPS before version SPS_E3_05.00.04.027.0 may allow an unauthenticated user to potentially enable escalation of privilege via physical access."}, {"lang": "es", "value": "Una vulnerabilidad de control de acceso insuficiente en el subsistema para Intel(R) CSME en versiones anteriores a la 11.x, 12.0.35 Intel(R) TXE 3.x, 4.x, Intel(R) Server Platform Services 3.x, 4.x, Intel(R) SPS en versiones anteriores a la SPS_E3_05.00.04.027.0 puede permitir que un usuario no autenticado habilite potencialmente un aumento de privilegios por medio de un acceso f\u00edsico."}], "id": "CVE-2019-0090", "lastModified": "2024-11-21T04:16:12.770", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 3.4, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "HIGH", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 0.5, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2019-05-17T16:29:00.937", "references": [{"source": "secure@intel.com", "tags": ["Third Party Advisory"], "url": "https://support.f5.com/csp/article/K59145983"}, {"source": "secure@intel.com", "tags": ["Vendor Advisory"], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00213.html"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory"], "url": "https://support.f5.com/csp/article/K59145983"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00213.html"}], "sourceIdentifier": "secure@intel.com", "vendorComments": [{"comment": "After an attacker gains access, they would need to invest additional effort in preparation or execution of the vulnerable component in order to use this vulnerability.", "lastModified": "2019-11-08T12:21:48.120", "organization": "Intel"}], "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "NVD-CWE-noinfo"}], "source": "nvd@nist.gov", "type": "Primary"}]}