Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:somachine_basic:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BCEA269-6242-41FD-B141-F72CAFC8F114", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F757A52E-2401-4A09-B53E-73135C5289A1", "versionEndExcluding": "1.10.0.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*", "matchCriteriaId": "BB0D83F4-B718-47AB-AFB8-B576CB138AAC", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic."}, {"lang": "es", "value": "Existe una vulnerabilidad de permisos predeterminados incorrectos (CWE-276) en SoMachine Basic, todas las versiones, y Modicon M221 (todas las referencias, todas las versiones anteriores al firmware V1.10.0.0), que podr\u00eda generar un acceso no autorizado a los archivos de recursos de SoMachine Basic cuando se logean en el System Hosting de SoMachine Basic."}], "id": "CVE-2018-7822", "lastModified": "2024-11-21T04:12:47.653", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "LOW", "cvssData": {"accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0"}, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2019-05-22T20:29:01.073", "references": [{"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-01/"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-276"}], "source": "nvd@nist.gov", "type": "Primary"}]}