Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:u.motion:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA2E9785-CC4B-4EB8-83A7-C851E921EEF2", "versionEndExcluding": "1.3.4", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application."}, {"lang": "es", "value": "En el software de Schneider Electric U.motion Builder en versiones anteriores a la v1.3.4, esta vulnerabilidad ocurre cuando los datos enviados de un string entrante se eval\u00faan como un comando por la aplicaci\u00f3n. De esta manera, el atacante podr\u00eda ejecutar c\u00f3digo, leer la pila o provocar un fallo de segmentaci\u00f3n en la aplicaci\u00f3n en ejecuci\u00f3n."}], "id": "CVE-2018-7784", "lastModified": "2024-11-21T04:12:43.767", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2018-07-03T14:29:01.523", "references": [{"source": "cybersecurity@se.com", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/104447"}, {"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/104447"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-20"}], "source": "nvd@nist.gov", "type": "Primary"}]}