Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:vyaire:carefusion_upgrade_utility:*:*:*:*:*:*:*:*", "matchCriteriaId": "7B2D1C6A-8C44-4993-9DC1-2A92F8B42A25", "versionEndIncluding": "2.0.2.2", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:o:microsoft:windows_xp:-:*:*:*:*:*:*:*", "matchCriteriaId": "B47EBFCC-1828-45AB-BC6D-FB980929A81A", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "A uncontrolled search path element issue was discovered in Vyaire Medical CareFusion Upgrade Utility used with Windows XP systems, Versions 2.0.2.2 and prior versions. A successful exploit of this vulnerability requires the local user to install a crafted DLL on the target machine. The application loads the DLL and gives the attacker access at the same privilege level as the application."}, {"lang": "es", "value": "Se ha descubierto un problema de elemento de ruta de b\u00fasqueda no controlado en Vyaire Medical CareFusion Upgrade Utility, empleado en sistemas Windows XP, en versiones 2.0.2.2 y anteriores. Una explotaci\u00f3n con \u00e9xito de esta vulnerabilidad requiere que el usuario local instale un DLL malicioso en la m\u00e1quina objetivo. La aplicaci\u00f3n carga el DLL y proporciona al atacante acceso al mismo nivel de privilegios que la aplicaci\u00f3n."}], "id": "CVE-2018-5457", "lastModified": "2024-11-21T04:08:50.283", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.9, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 3.4, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 1.0, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2018-02-06T21:29:00.473", "references": [{"source": "ics-cert@hq.dhs.gov", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/102983"}, {"source": "ics-cert@hq.dhs.gov", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-01"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/102983"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-01"}], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-427"}], "source": "ics-cert@hq.dhs.gov", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-427"}], "source": "nvd@nist.gov", "type": "Primary"}]}