Show plain JSON{"containers": {"cna": {"affected": [{"platforms": ["build 20200702"], "product": "QTS", "vendor": "QNAP Systems Inc.", "versions": [{"lessThan": "4.4.3.1354", "status": "affected", "version": "unspecified", "versionType": "custom"}]}], "credits": [{"lang": "en", "value": "Independent Security Evaluators"}], "datePublic": "2020-12-30T00:00:00", "descriptions": [{"lang": "en", "value": "A cleartext transmission of sensitive information vulnerability has been reported to affect certain QTS devices. If exploited, this vulnerability allows a remote attacker to gain access to sensitive information. QNAP have already fixed this vulnerability in the following versions: QTS 4.4.3.1354 build 20200702 (and later)"}], "problemTypes": [{"descriptions": [{"cweId": "CWE-311", "description": "CWE-311 Missing Encryption of Sensitive Data", "lang": "en", "type": "CWE"}]}, {"descriptions": [{"cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2020-12-31T16:33:27", "orgId": "2fd009eb-170a-4625-932b-17a53af1051f", "shortName": "qnap"}, "references": [{"tags": ["x_refsource_MISC"], "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22"}], "solutions": [{"lang": "en", "value": "QNAP have already fixed this vulnerability in the following versions:\nQTS 4.4.3.1354 build 20200702 (and later)"}], "source": {"advisory": "QSA-20-22", "discovery": "EXTERNAL"}, "title": "Cleartext Transmission of Sensitive Information in SNMP", "x_generator": {"engine": "Vulnogram 0.0.9"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "security@qnap.com", "DATE_PUBLIC": "2020-12-30T02:55:00.000Z", "ID": "CVE-2018-19944", "STATE": "PUBLIC", "TITLE": "Cleartext Transmission of Sensitive Information in SNMP"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "QTS", "version": {"version_data": [{"platform": "build 20200702", "version_affected": "<", "version_value": "4.4.3.1354"}]}}]}, "vendor_name": "QNAP Systems Inc."}]}}, "credit": [{"lang": "eng", "value": "Independent Security Evaluators"}], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "A cleartext transmission of sensitive information vulnerability has been reported to affect certain QTS devices. If exploited, this vulnerability allows a remote attacker to gain access to sensitive information. QNAP have already fixed this vulnerability in the following versions: QTS 4.4.3.1354 build 20200702 (and later)"}]}, "generator": {"engine": "Vulnogram 0.0.9"}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-311 Missing Encryption of Sensitive Data"}]}, {"description": [{"lang": "eng", "value": "CWE-319 Cleartext Transmission of Sensitive Information"}]}]}, "references": {"reference_data": [{"name": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22", "refsource": "MISC", "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22"}]}, "solution": [{"lang": "en", "value": "QNAP have already fixed this vulnerability in the following versions:\nQTS 4.4.3.1354 build 20200702 (and later)"}], "source": {"advisory": "QSA-20-22", "discovery": "EXTERNAL"}}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-05T11:51:17.673Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_MISC", "x_transferred"], "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22"}]}]}, "cveMetadata": {"assignerOrgId": "2fd009eb-170a-4625-932b-17a53af1051f", "assignerShortName": "qnap", "cveId": "CVE-2018-19944", "datePublished": "2020-12-31T16:33:27.820049Z", "dateReserved": "2018-12-07T00:00:00", "dateUpdated": "2024-09-17T02:11:00.534Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}