Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:opticam:i5_application_firmware:2.21.1.128:*:*:*:*:*:*:*", "matchCriteriaId": "42E72BBD-5418-4C2C-B8EB-997224A0CA01", "vulnerable": true}, {"criteria": "cpe:2.3:o:opticam:i5_system_firmware:1.5.2.11:*:*:*:*:*:*:*", "matchCriteriaId": "B9E1C7BD-97E3-41F9-BC4D-9C7320C471EE", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:opticam:i5:-:*:*:*:*:*:*:*", "matchCriteriaId": "670C0300-3A68-4AC1-B659-7727FF92D8E6", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:foscam:c2_application_firmware:2.72.1.32:*:*:*:*:*:*:*", "matchCriteriaId": "05CCF2DD-D69B-4518-B20A-376C98E2D02E", "vulnerable": true}, {"criteria": "cpe:2.3:o:foscam:c2_system_firmware:1.11.1.8:*:*:*:*:*:*:*", "matchCriteriaId": "28AD15E7-51C8-4B2D-BCEB-8EF2AA0B61A5", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:foscam:c2:-:*:*:*:*:*:*:*", "matchCriteriaId": "107D84D0-9D16-4930-A312-38B7586B4B4F", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The admin account has a blank password."}, {"lang": "es", "value": "Se ha descubierto un problema en dispositivos Foscam C2 con firmware del sistema 1.11.1.8 y firmware de aplicaci\u00f3n 2.72.1.32, as\u00ed como dispositivos Opticam i5 con firmware del sistema 1.5.2.11 y firmware de aplicaci\u00f3n 2.21.1.128. La cuenta de administrador tiene una contrase\u00f1a en blanco."}], "id": "CVE-2018-19063", "lastModified": "2024-11-21T03:57:15.283", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2018-11-07T18:29:00.523", "references": [{"source": "cve@mitre.org", "tags": ["Exploit", "Third Party Advisory"], "url": "https://sintonen.fi/advisories/foscam-ip-camera-multiple-vulnerabilities.txt"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Third Party Advisory"], "url": "https://sintonen.fi/advisories/foscam-ip-camera-multiple-vulnerabilities.txt"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-798"}], "source": "nvd@nist.gov", "type": "Primary"}]}