Show plain JSON{"cisaActionDue": "2022-05-03", "cisaExploitAdd": "2021-11-03", "cisaRequiredAction": "Apply updates per vendor instructions.", "cisaVulnerabilityName": "Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability", "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B16592CE-98A8-478A-94E1-DF628ADE67E7", "versionEndIncluding": "15.03.06.44_cn", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73D523BB-7EB3-4125-90C4-4C85F4AE1815", "versionEndIncluding": "15.03.05.19\\(6318\\)_cn", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9BDE03D1-5D87-4FCD-BB03-D483AB9BC186", "versionEndIncluding": "15.03.06.23_cn", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input."}, {"lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 con firmware hasta la versi\u00f3n V15.03.06.44_CN(AC7), dispositivos AC9 devices con firmware hasta la versi\u00f3n V15.03.05.19(6318)_CN(AC9) y dispositivos AC10 con firmware hasta la versi\u00f3n V15.03.06.23_CN(AC10). Una vulnerabilidad de inyecci\u00f3n de comandos permite que los atacantes ejecuten comandos arbitrarios del sistema operativo mediante una petici\u00f3n goform/setUsbUnload. Esto ocurre debido a que la funci\u00f3n \"formsetUsbUnload\" ejecuta una funci\u00f3n dosystemCmd con entradas no fiables."}], "id": "CVE-2018-14558", "lastModified": "2025-03-20T21:03:53.180", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}]}, "published": "2018-10-30T18:29:00.580", "references": [{"source": "cve@mitre.org", "tags": ["Exploit", "Third Party Advisory", "Broken Link"], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Third Party Advisory", "Broken Link"], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-78"}], "source": "nvd@nist.gov", "type": "Primary"}, {"description": [{"lang": "en", "value": "CWE-78"}], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}]}