Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:universal-robots:cb3.1_firmware:3.4.5-100:*:*:*:*:*:*:*", "matchCriteriaId": "7DBF23CE-E61B-4EDF-80D5-261F901CA957", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:universal-robots:cb3.1:-:*:*:*:*:*:*:*", "matchCriteriaId": "6646769C-25A1-4558-A229-62AF8B1FE167", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100 utilizes hard-coded credentials that may allow an attacker to reset passwords for the controller."}, {"lang": "es", "value": "Universal Robots Robot Controllers en versi\u00f3n CB 3.1, software en versi\u00f3n 3.4.5-100, utiliza credenciales embebidas que podr\u00edan permitir que un atacante reinicie contrase\u00f1as para el controlador."}], "id": "CVE-2018-10633", "lastModified": "2024-11-21T03:41:42.273", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2018-07-11T17:29:00.287", "references": [{"source": "ics-cert@hq.dhs.gov", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/104710"}, {"source": "ics-cert@hq.dhs.gov", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource"], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-01"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/104710"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource"], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-01"}], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vendorComments": [{"comment": "Starting with software version 5.10 (e-series), it is possible to set system administrator credentials. Universal Robots recommends that all users change the default password and securely document the password.\n\nCB2 and CB3 cobots are designed to be operating in factory networks where security relies on boundary protection (firewalls) and trusted clients on the network. They must only be connected to trusted networks and operated by authorized personnel.\n", "lastModified": "2022-04-12T13:41:59.347", "organization": "Universal Robots"}], "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-798"}], "source": "ics-cert@hq.dhs.gov", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-798"}], "source": "nvd@nist.gov", "type": "Primary"}]}