Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:medtronic:mycarelink_24952_patient_monitor_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4008DB3-E151-41BA-A308-7BE733268845", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:medtronic:mycarelink_24952_patient_monitor:-:*:*:*:*:*:*:*", "matchCriteriaId": "60267DCC-89D0-48E3-B6EB-9AD60DC1F16F", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:medtronic:mycarelink_24950_patient_monitor_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8AACDB33-1EC3-44E1-8C1C-38C766E85F85", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:medtronic:mycarelink_24950_patient_monitor:-:*:*:*:*:*:*:*", "matchCriteriaId": "BCDA4070-6CDD-42CA-A4A8-DA6B0E98C64D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected products use per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest."}, {"lang": "es", "value": "Se ha descubierto una vulnerabilidad en todas las versiones de Medtronic MyCareLink Patient Monitor 24950 y 24952. Los productos afectados emplean credenciales por producto que se almacenan en un formato recuperable. Un atacante puede emplear estas credenciales para autenticarse en red y cifrar datos locales en reposo."}], "id": "CVE-2018-10622", "lastModified": "2024-11-21T03:41:41.067", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "LOW", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 1.9, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0"}, "exploitabilityScore": 3.4, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "HIGH", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 0.5, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2018-08-10T18:29:00.230", "references": [{"source": "ics-cert@hq.dhs.gov", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/105042"}, {"source": "ics-cert@hq.dhs.gov", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "VDB Entry"], "url": "http://www.securityfocus.com/bid/105042"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01"}], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-257"}], "source": "ics-cert@hq.dhs.gov", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-522"}], "source": "nvd@nist.gov", "type": "Primary"}]}