Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:jenkins:z\\/os_connector:*:*:*:*:*:jenkins:*:*", "matchCriteriaId": "C2276A66-2195-42B5-AE23-ACACFFA9F968", "versionEndIncluding": "1.2.6.1", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "A exposure of sensitive information vulnerability exists in Jenkins z/OS Connector Plugin 1.2.6.1 and earlier in SCLMSCM.java that allows an attacker with local file system access or control of a Jenkins administrator's web browser (e.g. malicious extension) to retrieve the configured password."}, {"lang": "es", "value": "Existe una vulnerabilidad de exposici\u00f3n de informaci\u00f3n sensible en Jenkins z/OS Connector Plugin, en versiones 1.2.6.1 y anteriores, en SCLMSCM.java que permite que un atacante con acceso al sistema de archivos local o con el control del navegador web (por ejemplo, por una extensi\u00f3n maliciosa) de un administrador de Jenkins recupere la contrase\u00f1a configurada."}], "id": "CVE-2018-1000608", "lastModified": "2024-11-21T03:40:13.187", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0"}, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV30": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0"}, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2018-06-26T17:29:00.617", "references": [{"source": "cve@mitre.org", "tags": ["Vendor Advisory"], "url": "https://jenkins.io/security/advisory/2018-06-25/#SECURITY-950"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://jenkins.io/security/advisory/2018-06-25/#SECURITY-950"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-522"}], "source": "nvd@nist.gov", "type": "Primary"}]}