Show plain JSON{"containers": {"cna": {"affected": [{"product": "Primary Setup Tool (PST)", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V4.2 HF1"}]}, {"product": "SIMATIC Automation Tool", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V3.0"}]}, {"product": "SIMATIC NET PC-Software", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V14 SP1"}]}, {"product": "SIMATIC PCS 7 V8.1", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions"}]}, {"product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V8.2 SP1"}]}, {"product": "SIMATIC STEP 7 (TIA Portal) V13", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V13 SP2"}]}, {"product": "SIMATIC STEP 7 (TIA Portal) V14", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V14 SP1"}]}, {"product": "SIMATIC STEP 7 V5.X", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V5.6"}]}, {"product": "SIMATIC WinAC RTX 2010 SP2", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions"}]}, {"product": "SIMATIC WinAC RTX F 2010 SP2", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions"}]}, {"product": "SIMATIC WinCC (TIA Portal) V13", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V13 SP2"}]}, {"product": "SIMATIC WinCC (TIA Portal) V14", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V14 SP1"}]}, {"product": "SIMATIC WinCC V7.2 and prior", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions"}]}, {"product": "SIMATIC WinCC V7.3", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V7.3 Update 15"}]}, {"product": "SIMATIC WinCC V7.4", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V7.4 SP1 Upd1"}]}, {"product": "SIMATIC WinCC flexible 2008", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < flexible 2008 SP5"}]}, {"product": "SINAUT ST7CC", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15"}]}, {"product": "SINEMA Server", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V14"}]}, {"product": "SINUMERIK 808D Programming Tool", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V4.7 SP4 HF2"}]}, {"product": "SMART PC Access", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V2.3"}]}, {"product": "STEP 7 - Micro/WIN SMART", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V2.3"}]}, {"product": "Security Configuration Tool (SCT)", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V5.0"}]}, {"product": "Security Configuration Tool (SCT)", "vendor": "Siemens AG", "versions": [{"status": "affected", "version": "All versions < V5.0"}]}], "datePublic": "2017-05-10T00:00:00", "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover."}], "problemTypes": [{"descriptions": [{"description": "Other", "lang": "en", "type": "text"}]}], "providerMetadata": {"dateUpdated": "2019-03-21T15:44:20", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens"}, "references": [{"tags": ["x_refsource_CONFIRM"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"}, {"name": "98366", "tags": ["vdb-entry", "x_refsource_BID"], "url": "https://www.securityfocus.com/bid/98366"}], "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "productcert@siemens.com", "ID": "CVE-2017-6865", "STATE": "PUBLIC"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "Primary Setup Tool (PST)", "version": {"version_data": [{"version_value": "All versions < V4.2 HF1"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC Automation Tool", "version": {"version_data": [{"version_value": "All versions < V3.0"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC NET PC-Software", "version": {"version_data": [{"version_value": "All versions < V14 SP1"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC PCS 7 V8.1", "version": {"version_data": [{"version_value": "All versions"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC PCS 7 V8.2", "version": {"version_data": [{"version_value": "All versions < V8.2 SP1"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC STEP 7 (TIA Portal) V13", "version": {"version_data": [{"version_value": "All versions < V13 SP2"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC STEP 7 (TIA Portal) V14", "version": {"version_data": [{"version_value": "All versions < V14 SP1"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC STEP 7 V5.X", "version": {"version_data": [{"version_value": "All versions < V5.6"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC WinAC RTX 2010 SP2", "version": {"version_data": [{"version_value": "All versions"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC WinAC RTX F 2010 SP2", "version": {"version_data": [{"version_value": "All versions"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC WinCC (TIA Portal) V13", "version": {"version_data": [{"version_value": "All versions < V13 SP2"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC WinCC (TIA Portal) V14", "version": {"version_data": [{"version_value": "All versions < V14 SP1"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC WinCC V7.2 and prior", "version": {"version_data": [{"version_value": "All versions"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC WinCC V7.3", "version": {"version_data": [{"version_value": "All versions < V7.3 Update 15"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC WinCC V7.4", "version": {"version_data": [{"version_value": "All versions < V7.4 SP1 Upd1"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SIMATIC WinCC flexible 2008", "version": {"version_data": [{"version_value": "All versions < flexible 2008 SP5"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SINAUT ST7CC", "version": {"version_data": [{"version_value": "All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SINEMA Server", "version": {"version_data": [{"version_value": "All versions < V14"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SINUMERIK 808D Programming Tool", "version": {"version_data": [{"version_value": "All versions < V4.7 SP4 HF2"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "SMART PC Access", "version": {"version_data": [{"version_value": "All versions < V2.3"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "STEP 7 - Micro/WIN SMART", "version": {"version_data": [{"version_value": "All versions < V2.3"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "Security Configuration Tool (SCT)", "version": {"version_data": [{"version_value": "All versions < V5.0"}]}}]}, "vendor_name": "Siemens AG"}, {"product": {"product_data": [{"product_name": "Security Configuration Tool (SCT)", "version": {"version_data": [{"version_value": "All versions < V5.0"}]}}]}, "vendor_name": "Siemens AG"}]}}, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "Other"}]}]}, "references": {"reference_data": [{"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"}, {"name": "98366", "refsource": "BID", "url": "https://www.securityfocus.com/bid/98366"}]}}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-05T15:41:17.697Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"}, {"name": "98366", "tags": ["vdb-entry", "x_refsource_BID", "x_transferred"], "url": "https://www.securityfocus.com/bid/98366"}]}]}, "cveMetadata": {"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-6865", "datePublished": "2017-05-11T10:00:00", "dateReserved": "2017-03-13T00:00:00", "dateUpdated": "2024-08-05T15:41:17.697Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}