Filtered by vendor Bosch
Subscriptions
Filtered by product Cpp13 Firmware
Subscriptions
Total
8 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-32229 | 1 Bosch | 17 Autodome 7000i, Autodome 7100 Ir, Autodome Inteox 7000i and 14 more | 2024-12-12 | 4.9 Medium |
Due to an error in the software interface to the secure element chip on Bosch IP cameras of family CPP13 and CPP14, the chip can be permanently damaged when enabling the Stream security option (signing of the video stream) with option MD5, SHA-1 or SHA-256. | ||||
CVE-2022-41677 | 1 Bosch | 12 Cpp13, Cpp13 Firmware, Cpp14 and 9 more | 2024-11-27 | 5.3 Medium |
An information disclosure vulnerability was discovered in Bosch IP camera devices allowing an unauthenticated attacker to retrieve information (like capabilities) about the device itself and network settings of the device, disclosing possibly internal network settings if the device is connected to the internet. | ||||
CVE-2023-39509 | 1 Bosch | 4 Cpp13, Cpp13 Firmware, Cpp14 and 1 more | 2024-11-21 | 7.2 High |
A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera. | ||||
CVE-2021-23854 | 1 Bosch | 8 Cpp13, Cpp13 Firmware, Cpp6 and 5 more | 2024-11-21 | 8.3 High |
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected. | ||||
CVE-2021-23853 | 1 Bosch | 10 Cpp13, Cpp13 Firmware, Cpp4 and 7 more | 2024-11-21 | 8.3 High |
In Bosch IP cameras, improper validation of the HTTP header allows an attacker to inject arbitrary HTTP headers through crafted URLs. | ||||
CVE-2021-23852 | 1 Bosch | 10 Cpp13, Cpp13 Firmware, Cpp4 and 7 more | 2024-11-21 | 4.9 Medium |
An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS). | ||||
CVE-2021-23849 | 1 Bosch | 14 Aviotec, Aviotec Firmware, Cpp13 and 11 more | 2024-11-21 | 7.5 High |
A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or opening a malicious website while being logged in into the camera. | ||||
CVE-2021-23848 | 1 Bosch | 10 Cpp13, Cpp13 Firmware, Cpp4 and 7 more | 2024-11-21 | 8.3 High |
An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context of the user. |
Page 1 of 1.