Filtered by vendor Juniper Subscriptions
Filtered by product Acx2100 Subscriptions
Total 4 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-28961 1 Juniper 20 Acx1000, Acx1100, Acx2000 and 17 more 2024-11-21 5.8 Medium
An Improper Handling of Unexpected Data Type vulnerability in IPv6 firewall filter processing of Juniper Networks Junos OS on the ACX Series devices will prevent a firewall filter with the term 'from next-header ah' from being properly installed in the packet forwarding engine (PFE). There is no immediate indication of an incomplete firewall filter commit shown at the CLI, which could allow an attacker to send valid packets to or through the device that were explicitly intended to be dropped. An indication that the filter was not installed can be identified with the following logs: fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_rule_prepare : Config failed: Unsupported Ip-protocol 51 in the filter lo0.0-inet6-i fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_rule_prepare : Please detach the filter, remove unsupported match and re-attach fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_process_rule : Status:104 dnx_dfw_rule_prepare failed fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_process_filter : Status:104 dnx_dfw_process_rule failed fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_update_filter_in_hw : Status:104 Could not process filter(lo0.0-inet6-i) for rule expansion Unsupported match, action present. fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_create_hw_instance : Status:104 Could not program dfw(lo0.0-inet6-i) type(IFP_DFLT_INET6_Lo0_FILTER)! [104] fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_bind_shim : [104] Could not create dfw(lo0.0-inet6-i) type(IFP_DFLT_INET6_Lo0_FILTER) fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_update_resolve : [100] Failed to bind filter(3) to bind point fpc0 ACX_DFW_CFG_FAILED: ACX Error (dfw):dnx_dfw_change_end : dnx_dfw_update_resolve (resolve type) failed This issue affects Juniper Networks Junos OS on ACX Series: All versions prior to 20.2R3-S7; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3; 21.4 versions prior to 21.4R3; 22.1 versions prior to 22.1R2.
CVE-2021-31376 1 Juniper 9 Acx1000, Acx1100, Acx2100 and 6 more 2024-11-21 7.5 High
An Improper Input Validation vulnerability in Packet Forwarding Engine manager (FXPC) process of Juniper Networks Junos OS allows an attacker to cause a Denial of Service (DoS) by sending specific DHCPv6 packets to the device and crashing the FXPC service. Continued receipt and processing of this specific packet will create a sustained Denial of Service (DoS) condition. This issue affects only the following platforms in ACX Series: ACX500, ACX1000, ACX1100, ACX2100, ACX2200, ACX4000, ACX5048, ACX5096 devices. Other ACX platforms are not affected from this issue. This issue affects Juniper Networks Junos OS on ACX500, ACX1000, ACX1100, ACX2100, ACX2200, ACX4000, ACX5048, ACX5096: 18.4 version 18.4R3-S7 and later versions prior to 18.4R3-S8. This issue does not affect: Juniper Networks Junos OS 18.4 versions prior to 18.4R3-S7 on ACX500, ACX1000, ACX1100, ACX2100, ACX2200, ACX4000, ACX5048, ACX5096.
CVE-2021-0289 1 Juniper 229 Acx1000, Acx1100, Acx2000 and 226 more 2024-11-21 6.5 Medium
When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved.
CVE-2019-0043 1 Juniper 47 Acx1000, Acx1100, Acx2000 and 44 more 2024-11-21 7.5 High
In MPLS environments, receipt of a specific SNMP packet may cause the routing protocol daemon (RPD) process to crash and restart. By continuously sending a specially crafted SNMP packet, an attacker can repetitively crash the RPD process causing prolonged denial of service. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS : 12.1X46 versions prior to 12.1X46-D77 on SRX Series; 12.3 versions prior to 12.3R12-S10; 12.3X48 versions prior to 12.3X48-D75 on SRX Series; 14.1X53 versions prior to 14.1X53-D48 on EX/QFX series; 15.1 versions prior to 15.1R4-S9, 15.1R7-S2; 15.1F6 versions prior to 15.1F6-S11; 15.1X49 versions prior to 15.1X49-D141, 15.1X49-D144, 15.1X49-D150 on SRX Series; 15.1X53 versions prior to 15.1X53-D234 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D68 on QFX10K Series; 15.1X53 versions prior to 15.1X53-D471, 15.1X53-D490 on NFX Series; 15.1X53 versions prior to 15.1X53-D590 on EX2300/EX3400 Series; 15.1X54 on ACX Series; 16.1 versions prior to 16.1R3-S10, 16.1R4-S11, 16.1R6-S5, 16.1R7; 16.1X65 versions prior to 16.1X65-D48; 16.2 versions prior to 16.2R2-S6; 17.1 versions prior to 17.1R2-S8, 17.1R3; 17.2 versions prior to 17.2R1-S7, 17.2R3; 17.2X75 versions prior to 17.2X75-D92, 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R3; 17.4 versions prior to 17.4R1-S4, 17.4R2; 18.1 versions prior to 18.1R1-S1, 18.1R2-S1, 18.1R3; 18.2X75 versions prior to 18.2X75-D10.