Filtered by vendor Siemens
Subscriptions
Total
1930 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2011-4514 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2024-11-21 | N/A |
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. | ||||
CVE-2011-4513 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2024-11-21 | N/A |
Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader. | ||||
CVE-2011-4512 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2024-11-21 | N/A |
CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors. | ||||
CVE-2011-4511 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2024-11-21 | N/A |
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. | ||||
CVE-2011-4510 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2024-11-21 | N/A |
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. | ||||
CVE-2011-4509 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2024-11-21 | N/A |
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests. | ||||
CVE-2011-4508 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2024-11-21 | N/A |
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. | ||||
CVE-2011-4056 | 1 Siemens | 1 Tecnomatix Factorylink | 2024-11-21 | N/A |
An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method. | ||||
CVE-2011-4055 | 1 Siemens | 1 Tecnomatix Factorylink | 2024-11-21 | N/A |
Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL. | ||||
CVE-2011-3389 | 9 Canonical, Debian, Google and 6 more | 21 Ubuntu Linux, Debian Linux, Chrome and 18 more | 2024-11-21 | N/A |
The SSL protocol, as used in certain configurations in Microsoft Windows and Microsoft Internet Explorer, Mozilla Firefox, Google Chrome, Opera, and other products, encrypts data by using CBC mode with chained initialization vectors, which allows man-in-the-middle attackers to obtain plaintext HTTP headers via a blockwise chosen-boundary attack (BCBA) on an HTTPS session, in conjunction with JavaScript code that uses (1) the HTML5 WebSocket API, (2) the Java URLConnection API, or (3) the Silverlight WebClient API, aka a "BEAST" attack. | ||||
CVE-2011-3321 | 1 Siemens | 2 Simatic Wincc Flexible Runtime, Simatic Wincc Runtime | 2024-11-21 | N/A |
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. | ||||
CVE-2010-2772 | 1 Siemens | 2 Simatic Pcs 7, Simatic Wincc | 2024-11-21 | 7.8 High |
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. | ||||
CVE-2009-3322 | 1 Siemens | 1 Gigaset Se361 Wlan Router | 2024-11-21 | N/A |
The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723. | ||||
CVE-2009-1152 | 1 Siemens | 1 Gigaset Se461 Wimax Router | 2024-11-21 | N/A |
Siemens Gigaset SE461 WiMAX router 1.5-BL024.9.6401, and possibly other versions, allows remote attackers to cause a denial of service (device restart and loss of configuration) by connecting to TCP port 53, then closing the connection. | ||||
CVE-2008-7065 | 1 Siemens | 2 Gigaset C450 Ip, Gigaset C475 Ip | 2024-11-21 | N/A |
Siemens C450 IP and C475 IP VoIP devices allow remote attackers to cause a denial of service (disconnected calls and device reboot) via a crafted SIP packet to UDP port 5060. | ||||
CVE-2008-6993 | 1 Siemens | 1 Gigaset Wlan Camera | 2024-11-21 | N/A |
Siemens Gigaset WLAN Camera 1.27 has an insecure default password, which allows remote attackers to conduct unauthorized activities. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information. | ||||
CVE-2008-6916 | 2 John Doe, Siemens | 2 Netport Software, Speedstream 5200 | 2024-11-21 | N/A |
Siemens SpeedStream 5200 with NetPort Software 1.1 allows remote attackers to bypass authentication via an invalid Host header, possibly involving a trailing dot in the hostname. | ||||
CVE-2008-3972 | 2 Opensc-project, Siemens | 2 Opensc, Cardos | 2024-11-21 | N/A |
pkcs15-tool in OpenSC before 0.11.6 does not apply security updates to a smart card unless the card's label matches the "OpenSC" string, which might allow physically proximate attackers to exploit vulnerabilities that the card owner expected were patched, as demonstrated by exploitation of CVE-2008-2235. | ||||
CVE-2008-2235 | 2 Opensc-project, Siemens | 2 Opensc, Cardos | 2024-11-21 | N/A |
OpenSC before 0.11.5 uses weak permissions (ADMIN file control information of 00) for the 5015 directory on smart cards and USB crypto tokens running Siemens CardOS M4, which allows physically proximate attackers to change the PIN. | ||||
CVE-2008-1267 | 1 Siemens | 1 Speedstream 6520 | 2024-11-21 | N/A |
The Siemens SpeedStream 6520 router allows remote attackers to cause a denial of service (web interface crash) via an HTTP request to basehelp_English.htm with a large integer in the Content-Length field. |