Filtered by CWE-78
Filtered by vendor Subscriptions
Total 4128 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2018-0433 1 Cisco 12 Vbond Orchestrator, Vedge 100, Vedge 1000 and 9 more 2024-11-26 7.8 High
A vulnerability in the command-line interface (CLI) in the Cisco SD-WAN Solution could allow an authenticated, local attacker to inject arbitrary commands that are executed with root privileges. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by authenticating to the device and submitting crafted input to the CLI utility. The attacker must be authenticated to access the CLI utility. A successful exploit could allow the attacker to execute commands with root privileges.
CVE-2024-9461 1 Boldgrid 1 Total Upkeep 2024-11-26 7.2 High
The Total Upkeep – WordPress Backup Plugin plus Restore & Migrate by BoldGrid plugin for WordPress is vulnerable to Remote Code Execution in all versions up to, and including, 1.16.6 via the cron_interval parameter. This is due to missing input validation and sanitization. This makes it possible for authenticated attackers, with Administrator-level access and above, to execute code on the server.
CVE-2018-0453 1 Cisco 1 Firepower Threat Defense 2024-11-26 N/A
A vulnerability in the Sourcefire tunnel control channel protocol in Cisco Firepower System Software running on Cisco Firepower Threat Defense (FTD) sensors could allow an authenticated, local attacker to execute specific CLI commands with root privileges on the Cisco Firepower Management Center (FMC), or through Cisco FMC on other Firepower sensors and devices that are controlled by the same Cisco FMC. To send the commands, the attacker must have root privileges for at least one affected sensor or the Cisco FMC. The vulnerability exists because the affected software performs insufficient checks for certain CLI commands, if the commands are executed via a Sourcefire tunnel connection. An attacker could exploit this vulnerability by authenticating with root privileges to a Firepower sensor or Cisco FMC, and then sending specific CLI commands to the Cisco FMC or through the Cisco FMC to another Firepower sensor via the Sourcefire tunnel connection. A successful exploit could allow the attacker to modify device configurations or delete files on the device that is running Cisco FMC Software or on any Firepower device that is managed by Cisco FMC.
CVE-2018-0477 1 Cisco 1 Ios Xe 2024-11-26 6.7 Medium
A vulnerability in the CLI parser of Cisco IOS XE Software could allow an authenticated, local attacker to execute commands on the underlying Linux shell of an affected device with root privileges. The vulnerability exist because the affected software improperly sanitizes command arguments, failing to prevent access to certain internal data structures on an affected device. An attacker who has privileged EXEC mode (privilege level 15) access to an affected device could exploit these vulnerabilities on the device by executing CLI commands that contain custom arguments. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the affected device.
CVE-2018-0481 1 Cisco 1 Ios Xe 2024-11-26 6.7 Medium
A vulnerability in the CLI parser of Cisco IOS XE Software could allow an authenticated, local attacker to execute commands on the underlying Linux shell of an affected device with root privileges. The vulnerability exist because the affected software improperly sanitizes command arguments, failing to prevent access to certain internal data structures on an affected device. An attacker who has privileged EXEC mode (privilege level 15) access to an affected device could exploit these vulnerabilities on the device by executing CLI commands that contain custom arguments. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the affected device.
CVE-2018-15368 1 Cisco 1 Ios Xe 2024-11-26 6.7 Medium
A vulnerability in the CLI parser of Cisco IOS XE Software could allow an authenticated, local attacker to gain access to the underlying Linux shell of an affected device and execute arbitrary commands with root privileges on the device. The vulnerability is due to the affected software improperly sanitizing command arguments to prevent modifications to the underlying Linux filesystem on a device. An attacker who has privileged EXEC mode (privilege level 15) access to an affected device could exploit this vulnerability on the device by executing CLI commands that contain crafted arguments. A successful exploit could allow the attacker to gain access to the underlying Linux shell of the affected device and execute arbitrary commands with root privileges on the device.
CVE-2018-15442 1 Cisco 2 Webex Meetings Desktop, Webex Productivity Tools 2024-11-26 N/A
A vulnerability in the update service of Cisco Webex Meetings Desktop App for Windows could allow an authenticated, local attacker to execute arbitrary commands as a privileged user. The vulnerability is due to insufficient validation of user-supplied parameters. An attacker could exploit this vulnerability by invoking the update service command with a crafted argument. An exploit could allow the attacker to run arbitrary commands with SYSTEM user privileges. While the CVSS Attack Vector metric denotes the requirement for an attacker to have local access, administrators should be aware that in Active Directory deployments, the vulnerability could be exploited remotely by leveraging the operating system remote management tools.
CVE-2024-50359 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50360 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50366 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50368 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50369 2024-11-26 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50370 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
CVE-2024-50371 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
CVE-2024-50372 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
CVE-2024-50373 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
CVE-2024-50374 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
CVE-2024-50375 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 9.8 Critical
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
CVE-2024-50377 1 Advantech 3 Eki-6333ac-1gpo Firmware, Eki-6333ac-2g Firmware, Eki-6333ac-2gd Firmware 2024-11-26 6.5 Medium
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.
CVE-2024-50376 2024-11-26 7.3 High
A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.