CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-41156 | 2 Etm-s, Microsoft | 2 Ondiskplayeragent, Windows | 2024-11-21 | 7.8 High |
Remote code execution vulnerability due to insufficient verification of URLs, etc. in OndiskPlayerAgent. A remote attacker could exploit the vulnerability to cause remote code execution by causing an arbitrary user to download and execute malicious code. | ||||
CVE-2022-3703 | 1 Etictelecom | 14 Ras-c-100-lw, Ras-e-100, Ras-e-220 and 11 more | 2024-11-21 | 7.6 High |
All versions of ETIC Telecom Remote Access Server (RAS) 4.5.0 and prior’s web portal is vulnerable to accepting malicious firmware packages that could provide a backdoor to an attacker and provide privilege escalation to the device. | ||||
CVE-2022-3347 | 1 Go-resolver Project | 1 Go-resolver | 2024-11-21 | 7.5 High |
DNSSEC validation is not performed correctly. An attacker can cause this package to report successful validation for invalid, attacker-controlled records. Root DNSSEC public keys are not validated, permitting an attacker to present a self-signed root key and delegation chain. | ||||
CVE-2022-3346 | 1 Go-resolver Project | 1 Go-resolver | 2024-11-21 | 6.5 Medium |
DNSSEC validation is not performed correctly. An attacker can cause this package to report successful validation for invalid, attacker-controlled records. The owner name of RRSIG RRs is not validated, permitting an attacker to present the RRSIG for an attacker-controlled domain in a response for any other domain. | ||||
CVE-2022-39909 | 1 Samsung | 1 Gear Iconx Pc Manager | 2024-11-21 | 7.1 High |
Insufficient verification of data authenticity vulnerability in Samsung Gear IconX PC Manager prior to version 2.1.221019.51 allows local attackers to create arbitrary file using symbolic link. | ||||
CVE-2022-39199 | 1 Codenotary | 1 Immudb | 2024-11-21 | 5.8 Medium |
immudb is a database with built-in cryptographic proof and verification. immudb client SDKs use server's UUID to distinguish between different server instance so that the client can connect to different immudb instances and keep the state for multiple servers. SDK does not validate this uuid and can accept any value reported by the server. A malicious server can change the reported UUID tricking the client to treat it as a different server thus accepting a state completely irrelevant to the one previously retrieved from the server. This issue has been patched in version 1.4.1. As a workaround, when initializing an immudb client object a custom state handler can be used to store the state. Providing custom implementation that ignores the server UUID can be used to ensure that even if the server changes the UUID, client will still consider it to be the same server. | ||||
CVE-2022-38625 | 1 Patlite | 6 Nbm-d88n, Nbm-d88n Firmware, Nhl-3fb1 and 3 more | 2024-11-21 | 8.8 High |
Patlite NH-FB v1.46 and below was discovered to contain insufficient firmware validation during the upgrade firmware file upload process. This vulnerability allows authenticated attackers to create and upload their own custom-built firmware and inject malicious code. NOTE: the vendor's position is that this is a design choice, not a vulnerability | ||||
CVE-2022-37928 | 1 Hpe | 18 Hf20, Hf20 Firmware, Hf20c and 15 more | 2024-11-21 | 8 High |
Insufficient Verification of Data Authenticity vulnerability in Hewlett Packard Enterprise HPE Nimble Storage Hybrid Flash Arrays and Nimble Storage Secondary Flash Arrays. | ||||
CVE-2022-37008 | 1 Huawei | 3 Emui, Harmonyos, Magic Ui | 2024-11-21 | 7.5 High |
The recovery module has a vulnerability of bypassing the verification of an update package before use. Successful exploitation of this vulnerability may affect system stability. | ||||
CVE-2022-36360 | 1 Siemens | 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker to manipulate a firmware update and flash it to the device. | ||||
CVE-2022-36130 | 1 Hashicorp | 1 Boundary | 2024-11-21 | 9.9 Critical |
HashiCorp Boundary up to 0.10.1 did not properly perform data integrity checks to ensure the resources were associated with the correct scopes, allowing potential privilege escalation for authorized users of another scope. Fixed in Boundary 0.10.2. | ||||
CVE-2022-36111 | 1 Codenotary | 1 Immudb | 2024-11-21 | 5.4 Medium |
immudb is a database with built-in cryptographic proof and verification. In versions prior to 1.4.1, a malicious immudb server can provide a falsified proof that will be accepted by the client SDK signing a falsified transaction replacing the genuine one. This situation can not be triggered by a genuine immudb server and requires the client to perform a specific list of verified operations resulting in acceptance of an invalid state value. This vulnerability only affects immudb client SDKs, the immudb server itself is not affected by this vulnerability. This issue has been patched in version 1.4.1. | ||||
CVE-2022-34845 | 1 Robustel | 2 R1510, R1510 Firmware | 2024-11-21 | 2.7 Low |
A firmware update vulnerability exists in the sysupgrade functionality of Robustel R1510 3.1.16 and 3.3.0. A specially-crafted network packet can lead to arbitrary firmware update. An attacker can send a sequence of requests to trigger this vulnerability. | ||||
CVE-2022-34763 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.9 Medium |
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-32252 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-11-21 | 6.5 Medium |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker. | ||||
CVE-2022-31877 | 1 Msi | 1 Center | 2024-11-21 | 8.8 High |
An issue in the component MSI.TerminalServer.exe of MSI Center v1.0.41.0 allows attackers to escalate privileges via a crafted TCP packet. | ||||
CVE-2022-31813 | 4 Apache, Fedoraproject, Netapp and 1 more | 6 Http Server, Fedora, Clustered Data Ontap and 3 more | 2024-11-21 | 9.8 Critical |
Apache HTTP Server 2.4.53 and earlier may not send the X-Forwarded-* headers to the origin server based on client side Connection header hop-by-hop mechanism. This may be used to bypass IP based authentication on the origin server/application. | ||||
CVE-2022-31801 | 2 Phoenixcontact, Phoenixcontact-software | 3 Multiprog, Proconos, Proconos Eclr | 2024-11-21 | 9.8 Critical |
An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device. | ||||
CVE-2022-31800 | 1 Phoenixcontact | 34 Axc 1050, Axc 1050 Firmware, Axc 1050 Xc and 31 more | 2024-11-21 | 9.8 Critical |
An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device. | ||||
CVE-2022-31598 | 1 Sap | 1 Business Objects Business Intelligence Platform | 2024-11-21 | 5.4 Medium |
Due to insufficient input validation, SAP Business Objects - version 420, allows an authenticated attacker to submit a malicious request through an allowed operation. On successful exploitation, an attacker can view or modify information causing a limited impact on confidentiality and integrity of the application. |