Filtered by vendor Juniper Subscriptions
Total 1132 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2017-2312 1 Juniper 1 Junos 2025-04-20 N/A
On Juniper Networks devices running Junos OS affected versions and with LDP enabled, a specific LDP packet destined to the RE (Routing Engine) will consume a small amount of the memory allocated for the rpd (routing protocol daemon) process. Over time, repeatedly receiving this type of LDP packet(s) will cause the memory to exhaust and the rpd process to crash and restart. It is not possible to free up the memory that has been consumed without restarting the rpd process. This issue affects Junos OS based devices with either IPv4 or IPv6 LDP enabled via the [protocols ldp] configuration (the native IPv6 support for LDP is available in Junos OS 16.1 and higher). The interface on which the packet arrives needs to have LDP enabled. The affected Junos versions are: 13.3 prior to 13.3R10; 14.1 prior to 14.1R8; 14.2 prior to 14.2R7-S6 or 14.2R8; 15.1 prior to 15.1F2-S14, 15.1F6-S4, 15.1F7, 15.1R4-S7, 15.1R5; 15.1X49 before 15.1X49-D70; 15.1X53 before 15.1X53-D230, 15.1X53-D63, 15.1X53-D70; 16.1 before 16.1R2. 16.2R1 and all subsequent releases have a resolution for this vulnerability.
CVE-2017-2315 1 Juniper 1 Junos 2025-04-20 N/A
On Juniper Networks EX Series Ethernet Switches running affected Junos OS versions, a vulnerability in IPv6 processing has been discovered that may allow a specially crafted IPv6 Neighbor Discovery (ND) packet destined to an EX Series Ethernet Switch to cause a slow memory leak. A malicious network-based packet flood of these crafted IPv6 NDP packets may eventually lead to resource exhaustion and a denial of service. The affected Junos OS versions are: 12.3 prior to 12.3R12-S4, 12.3R13; 13.3 prior to 13.3R10; 14.1 prior to 14.1R8-S3, 14.1R9; 14.1X53 prior ro 14.1X53-D12, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R6-S4, 14.2R7-S6, 14.2R8; 15.1 prior to 15.1R5; 16.1 before 16.1R3; 16.2 before 16.2R1-S3, 16.2R2. 17.1R1 and all subsequent releases have a resolution for this vulnerability.
CVE-2016-4925 1 Juniper 1 Junose 2025-04-20 N/A
Receipt of a specifically malformed IPv6 packet processed by the router may trigger a line card reset: processor exception 0x68616c74 (halt) in task: scheduler. The line card will reboot and recover without user interaction. However, additional specifically malformed packets may cause follow-on line card resets and lead to an extended service outage. This issue only affects E Series routers with IPv6 licensed and enabled. Routers not configured to process IPv6 traffic are unaffected by this vulnerability. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-10605 1 Juniper 14 Junos, Srx100, Srx110 and 11 more 2025-04-20 N/A
On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series.
CVE-2016-4924 1 Juniper 1 Junos 2025-04-20 N/A
An incorrect permissions vulnerability in Juniper Networks Junos OS on vMX may allow local unprivileged users on a host system read access to vMX or vPFE images and obtain sensitive information contained in them such as private cryptographic keys. This issue was found during internal product security testing. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 15.1 prior to 15.1F5; 14.1 prior to 14.1R8
CVE-2016-4921 1 Juniper 1 Junos 2025-04-20 N/A
By flooding a Juniper Networks router running Junos OS with specially crafted IPv6 traffic, all available resources can be consumed, leading to the inability to store next hop information for legitimate traffic. In extreme cases, the crafted IPv6 traffic may result in a total resource exhaustion and kernel panic. The issue is triggered by traffic destined to the router. Transit traffic does not trigger the vulnerability. This issue only affects devices with IPv6 enabled and configured. Devices not configured to process IPv6 traffic are unaffected by this vulnerability. This issue was found during internal product security testing. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. Affected releases are Juniper Networks Junos OS 11.4 prior to 11.4R13-S3; 12.3 prior to 12.3R3-S4; 12.3X48 prior to 12.3X48-D30; 13.3 prior to 13.3R10, 13.3R4-S11; 14.1 prior to 14.1R2-S8, 14.1R4-S12, 14.1R8; 14.1X53 prior to 14.1X53-D28, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R3-S10, 14.2R4-S7, 14.2R6; 15.1 prior to 15.1F2-S5, 15.1F5-S2, 15.1F6, 15.1R3; 15.1X49 prior to 15.1X49-D40; 15.1X53 prior to 15.1X53-D57, 15.1X53-D70.
CVE-2017-10613 1 Juniper 1 Junos 2025-04-20 N/A
A vulnerability in a specific loopback filter action command, processed in a specific logical order of operation, in a running configuration of Juniper Networks Junos OS, allows an attacker with CLI access and the ability to initiate remote sessions to the loopback interface with the defined action, to hang the kernel. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55; 12.3X48 prior to 12.3X48-D35; 14.1 prior to 14.1R8-S4, 14.1R9; 14.1X53 prior to 14.1X53-D40; 14.2 prior to 14.2R4-S9, 14.2R7-S8, 14.2R8; 15.1 prior to 15.1F5-S3, 15.1F6, 15.1R4; 15.1X49 prior to 15.1X49-D60; 15.1X53 prior to 15.1X53-D47; 16.1 prior to 16.1R2. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-2341 1 Juniper 13 Acx5000, Ex4600, Junos and 10 more 2025-04-20 N/A
An insufficient authentication vulnerability on platforms where Junos OS instances are run in a virtualized environment, may allow unprivileged users on the Junos OS instance to gain access to the host operating environment, and thus escalate privileges. Affected releases are Juniper Networks Junos OS 14.1X53 prior to 14.1X53-D40 on QFX5110, QFX5200, QFX10002, QFX10008, QFX10016, EX4600 and NFX250; 15.1 prior to 15.1R5 on EX4600; 15.1X49 prior to 15.1X49-D70 on vSRX, SRX1500, SRX4100, SRX4200; 16.1 prior to 16.1R2 on EX4600, ACX5000 series. This issue does not affect vMX. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-10617 1 Juniper 1 Contrail 2025-04-20 5 Medium
The ifmap service that comes bundled with Contrail has an XML External Entity (XXE) vulnerability that may allow an attacker to retrieve sensitive system files. Affected releases are Juniper Networks Contrail 2.2 prior to 2.21.4; 3.0 prior to 3.0.3.4; 3.1 prior to 3.1.4.0; 3.2 prior to 3.2.5.0. CVE-2017-10616 and CVE-2017-10617 can be chained together and have a combined CVSSv3 score of 5.8 (AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N).
CVE-2017-10604 1 Juniper 2 Junos, Srx 2025-04-20 N/A
When the device is configured to perform account lockout with a defined period of time, any unauthenticated user attempting to log in as root with an incorrect password can trigger a lockout of the root account. When an SRX Series device is in cluster mode, and a cluster sync or failover operation occurs, then there will be errors associated with synch or failover while the root account is locked out. Administrators can confirm if the root account is locked out via the following command root@device> show system login lockout user root User Lockout start Lockout end root 1995-01-01 01:00:01 PDT 1995-11-01 01:31:01 PDT Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D65 on SRX series; 12.3X48 prior to 12.3X48-D45 on SRX series; 15.1X49 prior to 15.1X49-D75 on SRX series.
CVE-2017-10603 1 Juniper 1 Junos 2025-04-20 N/A
An XML injection vulnerability in Junos OS CLI can allow a locally authenticated user to elevate privileges and run arbitrary commands as the root user. This issue was found during internal product security testing. Affected releases are Juniper Networks Junos OS 15.1X53 prior to 15.1X53-D47, 15.1 prior to 15.1R3. Junos versions prior to 15.1 are not affected. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-10623 1 Juniper 1 Junos Space 2025-04-20 N/A
Lack of authentication and authorization of cluster messages in Juniper Networks Junos Space may allow a man-in-the-middle type of attacker to intercept, inject or disrupt Junos Space cluster operations between two nodes. Affected releases are Juniper Networks Junos Space all versions prior to 17.1R1.
CVE-2017-10620 1 Juniper 21 Junos, Srx100, Srx110 and 18 more 2025-04-20 N/A
Juniper Networks Junos OS on SRX series devices do not verify the HTTPS server certificate before downloading anti-virus updates. This may allow a man-in-the-middle attacker to inject bogus signatures to cause service disruptions or make the device not detect certain types of attacks. Affected Junos OS releases are: 12.1X46 prior to 12.1X46-D71; 12.3X48 prior to 12.3X48-D55; 15.1X49 prior to 15.1X49-D110;
CVE-2017-2345 1 Juniper 1 Junos 2025-04-20 N/A
On Junos OS devices with SNMP enabled, a network based attacker with unfiltered access to the RE can cause the Junos OS snmpd daemon to crash and restart by sending a crafted SNMP packet. Repeated crashes of the snmpd daemon can result in a partial denial of service condition. Additionally, it may be possible to craft a malicious SNMP packet in a way that can result in remote code execution. SNMP is disabled in Junos OS by default. Junos OS devices with SNMP disabled are not affected by this issue. No other Juniper Networks products or platforms are affected by this issue. NOTE: This is a different issue than Cisco CVE-2017-6736, CVE-2017-6737, and CVE-2017-6738. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67; 12.3X48 prior to 12.3X48-D51, 12.3X48-D55; 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R2-S10, 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D122, 14.1X53-D44, 14.1X53-D50; 14.2 prior to 14.2R4-S9, 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F2-S18, 15.1F6-S7, 15.1R4-S8, 15.1R5-S5, 15.1R6-S1, 15.1R7; 15.1X49 prior to 15.1X49-D100, 15.1X49-D110; 15.1X53 prior to 15.1X53-D231, 15.1X53-D47, 15.1X53-D48, 15.1X53-D57, 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R4-S4, 16.1R5; 16.2 prior to 16.2R2, 16.2R3; 17.1 prior to 17.1R1-S3, 17.1R2, 17.1R3; 17.2 prior to 17.2R1-S1, 17.2R2; 17.2X75 prior to 17.2X75-D30. Junos releases prior to 10.2 are not affected.
CVE-2017-10619 1 Juniper 7 Junos, Srx1400, Srx3400 and 4 more 2025-04-20 N/A
When Express Path (formerly known as service offloading) is configured on Juniper Networks SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800 in high availability cluster configuration mode, certain multicast packets might cause the flowd process to crash, halting or interrupting traffic from flowing through the device and triggering RG1+ (data-plane) fail-over to the secondary node. Repeated crashes of the flowd process may constitute an extended denial of service condition. This service is not enabled by default and is only supported in high-end SRX platforms. Affected releases are Juniper Networks Junos OS 12.3X48 prior to 12.3X48-D45, 15.1X49 prior to 15.1X49-D80 on SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800.
CVE-2017-10618 1 Juniper 1 Junos 2025-04-20 N/A
When the 'bgp-error-tolerance' feature â€" designed to help mitigate remote session resets from malformed path attributes â€" is enabled, a BGP UPDATE containing a specifically crafted set of transitive attributes can cause the RPD routing process to crash and restart. Devices with BGP enabled that do not have 'bgp-error-tolerance' configured are not vulnerable to this issue. Affected releases are Juniper Networks Junos OS 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D45, 14.1X53-D50; 14.2 prior to 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F5-S8, 15.1F6-S7, 15.1R5-S6, 15.1R6-S2, 15.1R7; 15.1X49 prior to 15.1X49-D100; 15.1X53 prior to 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R5; 16.2 prior to 16.2R1-S5, 16.2R2; 17.1 prior to 17.1R1-S3, 17.1R2; 17.2 prior to 17.2R1-S2, 17.2R2; 17.2X75 prior to 17.2X75-D50. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-2330 1 Juniper 1 Northstar Controller 2025-04-20 N/A
A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unauthenticated, local user, to create a fork bomb scenario, also known as a rabbit virus, or wabbit, which will create processes that replicate themselves, until all resources are consumed on the system, leading to a denial of service to the entire system until it is restarted. Continued attacks by an unauthenticated, local user, can lead to persistent denials of services.
CVE-2017-2348 1 Juniper 1 Junos 2025-04-20 N/A
The Juniper Enhanced jdhcpd daemon may experience high CPU utilization, or crash and restart upon receipt of an invalid IPv6 UDP packet. Both high CPU utilization and repeated crashes of the jdhcpd daemon can result in a denial of service as DHCP service is interrupted. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 14.1X53 prior to 14.1X53-D12, 14.1X53-D38, 14.1X53-D40 on QFX, EX, QFabric System; 15.1 prior to 15.1F2-S18, 15.1R4 on all products and platforms; 15.1X49 prior to 15.1X49-D80 on SRX; 15.1X53 prior to 15.1X53-D51, 15.1X53-D60 on NFX, QFX, EX.
CVE-2017-2306 1 Juniper 1 Junos Space 2025-04-20 N/A
On Juniper Networks Junos Space versions prior to 16.1R1, due to an insufficient authorization check, readonly users on the Junos Space administrative web interface can execute code on the device.
CVE-2017-2307 1 Juniper 1 Junos Space 2025-04-20 N/A
A reflected cross site scripting vulnerability in the administrative interface of Juniper Networks Junos Space versions prior to 16.1R1 may allow remote attackers to steal sensitive information or perform certain administrative actions on Junos Space.