Filtered by vendor Schneider-electric
Subscriptions
Total
803 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-11567 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured. | ||||
| CVE-2024-9002 | 1 Schneider-electric | 1 Easergy Studio | 2026-04-15 | 7.8 High |
| CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity, and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries | ||||
| CVE-2024-8531 | 1 Schneider-electric | 1 Data Center Expert | 2026-04-15 | 7.2 High |
| CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that could compromise the Data Center Expert software when an upgrade bundle is manipulated to include arbitrary bash scripts that are executed as root. | ||||
| CVE-2025-8453 | 1 Schneider-electric | 2 Saitel Dp, Saitel Dr | 2026-04-15 | 6.7 Medium |
| CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and arbitrary code execution when a privileged engineer user with console access modifies a configuration file used by a root-level daemon to execute custom scripts. | ||||
| CVE-2024-8936 | 1 Schneider-electric | 1 Modicon M340 | 2026-04-15 | 6.5 Medium |
| CWE-20: Improper Input Validation vulnerability exists that could lead to loss of confidentiality of controller memory after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call used to tamper with memory. | ||||
| CVE-2025-6625 | 1 Schneider-electric | 12 Bmxngd0100, Bmxngd0100 Firmware, Bmxnoc0401 and 9 more | 2026-04-15 | 7.5 High |
| CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device. | ||||
| CVE-2025-54925 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.5 High |
| CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url. | ||||
| CVE-2025-11566 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint. | ||||
| CVE-2025-11565 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload. | ||||
| CVE-2024-8938 | 1 Schneider-electric | 3 Modicon M340, Modicon Mc80, Modicon Momentum Unity M1e Processor | 2026-04-15 | 8.1 High |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation. | ||||
| CVE-2025-9996 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session. | ||||
| CVE-2025-8448 | 1 Schneider-electric | 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products. | ||||
| CVE-2025-9997 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session. | ||||
| CVE-2024-8518 | 1 Schneider-electric | 1 Zelio Soft 2 | 2026-04-15 | 3.3 Low |
| CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft 2 application when a specially crafted project file is loaded by an application user. | ||||
| CVE-2024-8933 | 1 Schneider-electric | 3 Modicon M340, Modicon Mc80, Modicon Momentum Unity M1e Processor | 2026-04-15 | 7.5 High |
| CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of confidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the logical network while a valid user uploads or downloads a project file into the controller. | ||||
| CVE-2024-8935 | 1 Schneider-electric | 3 Modicon M340 Bmxp341000, Modicon Mc80 Bmkc8020301, Modicon Momentum Unity M1e Processor | 2026-04-15 | 7.5 High |
| CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is inherent to Diffie Hellman algorithm which does not protect against Man-In-The-Middle attacks. | ||||
| CVE-2024-6918 | 1 Schneider-electric | 1 Accutech Manager | 2026-04-15 | 7.5 High |
| CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. | ||||
| CVE-2025-54926 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.2 High |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed. | ||||
| CVE-2024-10498 | 1 Schneider-electric | 1 Powerlogic Hdpm6000 | 2026-04-15 | 6.5 Medium |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality. | ||||
| CVE-2024-8530 | 1 Schneider-electric | 1 Data Center Expert | 2026-04-15 | 5.9 Medium |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS. | ||||
ReportizFlow