Filtered by vendor Lenovo
Subscriptions
Total
403 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2018-9086 | 1 Lenovo | 8 Thinkserver Rd340, Thinkserver Rd340 Firmware, Thinkserver Rd440 and 5 more | 2024-11-21 | N/A |
In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users. | ||||
CVE-2018-9085 | 2 Ibm, Lenovo | 56 Bladecenter, Bladecenter Hs23 Firmware, Bladecenter Hs23e Firmware and 53 more | 2024-11-21 | N/A |
A write protection lock bit was left unset after boot on an older generation of Lenovo and IBM System x servers, potentially allowing an attacker with administrator access to modify the subset of flash memory containing Intel Server Platform Services (SPS) and the system Flash Descriptors. | ||||
CVE-2018-9084 | 1 Lenovo | 8 System Management Module Firmware, Thinkagile Hx Enclosure 7x81, Thinkagile Hx Enclosure 7y87 and 5 more | 2024-11-21 | N/A |
In System Management Module (SMM) versions prior to 1.06, if an attacker manages to log in to the device OS, the validation of software updates can be circumvented. | ||||
CVE-2018-9083 | 1 Lenovo | 8 System Management Module Firmware, Thinkagile Hx Enclosure 7x81, Thinkagile Hx Enclosure 7y87 and 5 more | 2024-11-21 | N/A |
In System Management Module (SMM) versions prior to 1.06, the SMM contains weak default root credentials which could be used to log in to the device OS -- if the attacker manages to enable SSH or Telnet connections via some other vulnerability. | ||||
CVE-2018-9082 | 1 Lenovo | 40 Ez Media \& Backup Center, Ez Media \& Backup Center Firmware, Ix2 and 37 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the password changing functionality available to authenticated users does not require the user's current password to set a new one. As a result, attackers with access to the user's session tokens can change their password and retain access to the user's account | ||||
CVE-2018-9081 | 1 Lenovo | 40 Ez Media \& Backup Center, Ez Media \& Backup Center Firmware, Ix2 and 37 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the file name used for assets accessible through the Content Viewer application are vulnerable to self cross-site scripting self-XSS. As a result, adversaries can add files to shares accessible from the Content Viewer with a cross site scripting payload in its name, and wait for a user to try and rename the file for their payload to trigger. | ||||
CVE-2018-9080 | 1 Lenovo | 40 Ez Media \& Backup Center, Ez Media \& Backup Center Firmware, Ix2 and 37 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, by setting the Iomega cookie to a known value before logging into the NAS's web application, the NAS will not provide the user a new cookie value. This allows an attacker who knows the cookie's value to compromise the user's session. | ||||
CVE-2018-9079 | 1 Lenovo | 40 Ez Media \& Backup Center, Ez Media \& Backup Center Firmware, Ix2 and 37 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, adversaries can craft URLs to modify the Document Object Model (DOM) of the page. In addition, adversaries can inject HTML script tags and HTML tags with JavaScript handlers to execute arbitrary JavaScript with the origin of the device. | ||||
CVE-2018-9078 | 1 Lenovo | 40 Ez Media \& Backup Center, Ez Media \& Backup Center Firmware, Ix2 and 37 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the Content Explorer application grants users the ability to upload files to shares and this image was rendered in the browser in the device's origin instead of prompting to download the asset. The application does not prevent the user from uploading SVG images and returns these images within their origin. As a result, malicious users can upload SVG images that contain arbitrary JavaScript that is evaluated when the victim issues a request to download the file. | ||||
CVE-2018-9077 | 1 Lenovo | 22 Iomega Ez Media \& Backup Center, Iomega Storcenter Ix2, Iomega Storcenter Ix2-dl and 19 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, when changing the name of a share, an attacker can craft a command injection payload using backtick "``" characters in the share : name parameter. As a result, arbitrary commands may be executed as the root user. The attack requires a value __c and iomega parameter. | ||||
CVE-2018-9076 | 1 Lenovo | 22 Iomega Ez Media \& Backup Center, Iomega Storcenter Ix2, Iomega Storcenter Ix2-dl and 19 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, when changing the name of a share, an attacker can craft a command injection payload using backtick "``" characters in the name parameter. As a result, arbitrary commands may be executed as the root user. The attack requires a value __c and iomega parameter. | ||||
CVE-2018-9075 | 1 Lenovo | 22 Iomega Ez Media \& Backup Center, Iomega Storcenter Ix2, Iomega Storcenter Ix2-dl and 19 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, when joining a PersonalCloud setup, an attacker can craft a command injection payload using backtick "``" characters in the client:password parameter. As a result, arbitrary commands may be executed as the root user. The attack requires a value __c and iomega parameter. | ||||
CVE-2018-9074 | 1 Lenovo | 22 Iomega Ez Media \& Backup Center, Iomega Storcenter Ix2, Iomega Storcenter Ix2-dl and 19 more | 2024-11-21 | N/A |
For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the file upload functionality of the Content Explorer application is vulnerable to path traversal. As a result, users can upload files anywhere on the device's operating system as the root user. | ||||
CVE-2018-9073 | 1 Lenovo | 2 Chassis Management Module, Chassis Management Module Firmware | 2024-11-21 | N/A |
Lenovo Chassis Management Module (CMM) prior to version 2.0.0 utilizes a hardcoded encryption key to protect certain secrets. Possession of the key can allow an attacker that has already compromised the server to decrypt these secrets. | ||||
CVE-2018-9072 | 1 Lenovo | 1 Xclarity Integrator | 2024-11-21 | N/A |
In versions prior to 5.5, LXCI for VMware allows an authenticated user to download any system file due to insufficient input sanitization during file downloads. | ||||
CVE-2018-9071 | 1 Lenovo | 2 Chassis Management Module, Chassis Management Module Firmware | 2024-11-21 | N/A |
Lenovo Chassis Management Module (CMM) prior to version 2.0.0 allows unauthenticated users to retrieve information related to the current authentication configuration settings. Exposed settings relate to password lengths, expiration, and lockout configuration. | ||||
CVE-2018-9070 | 1 Lenovo | 1 Smart Assistant | 2024-11-21 | N/A |
For the Lenovo Smart Assistant Android app versions earlier than 12.1.82, an attacker with physical access to the smart speaker can, by pressing a specific button sequence, enter factory test mode and enable a web service intended for testing the device. As with most test modes, this provides extra privileges, including changing settings and running code. Lenovo Smart Assistant is an Amazon Alexa-enabled smart speaker developed by Lenovo. | ||||
CVE-2018-9069 | 2 Hp, Lenovo | 133 310s-14isk, 310s-14isk Firmware, 320-15ikbra and 130 more | 2024-11-21 | 5.9 Medium |
In some Lenovo IdeaPad consumer notebook models, a race condition in the BIOS flash device locking mechanism is not adequately protected against, potentially allowing an attacker with administrator access to alter the contents of BIOS. | ||||
CVE-2018-9068 | 2 Ibm, Lenovo | 84 Bladecenter Hs22, Bladecenter Hs22 Firmware, Bladecenter Hs23 and 81 more | 2024-11-21 | N/A |
The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI. | ||||
CVE-2018-9067 | 1 Lenovo | 1 Lenovo Help | 2024-11-21 | N/A |
The Lenovo Help Android app versions earlier than 6.1.2.0327 had insufficient access control for some functions which, if exploited, could have led to exposure of approximately 400 email addresses and 8,500 IMEI. |