Filtered by vendor
Subscriptions
Total
64 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-28008 | 1 Nec | 118 Aterm Cr2500p, Aterm Cr2500p Firmware, Aterm Mr01ln and 115 more | 2025-09-29 | 9.8 Critical |
Active Debug Code in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary OS command via the internet. | ||||
CVE-2024-9643 | 1 Four-faith | 2 F3x36, F3x36 Firmware | 2025-09-19 | 9.8 Critical |
The Four-Faith F3x36 router using firmware v2.0.0 is vulnerable to authentication bypass due to hard-coded credentials in the administrative web server. An attacker with knowledge of the credentials can gain administrative access via crafted HTTP requests. This issue appears similar to CVE-2023-32645. | ||||
CVE-2024-9644 | 1 Four-faith | 2 F3x36, F3x36 Firmware | 2025-09-19 | 9.8 Critical |
The Four-Faith F3x36 router using firmware v2.0.0 is vulnerable to an authentication bypass vulnerability in the administrative web server. Authentication is not enforced on some administrative functionality when using the "bapply.cgi" endpoint instead of the normal "apply.cgi" endpoint. A remote and unauthenticated can use this vulnerability to modify settings or chain with existing authenticated vulnerabilities. | ||||
CVE-2024-44092 | 1 Google | 1 Android | 2025-09-15 | 7.8 High |
There is a possible LCS signing enforcement missing due to test/debugging code left in a production build. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. | ||||
CVE-2025-36899 | 1 Google | 1 Android | 2025-09-05 | 8.4 High |
There is a possible escalation of privilege due to test/debugging code left in a production build. This could lead to physical escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. | ||||
CVE-2024-21827 | 1 Tp-link | 2 Er7206, Er7206 Firmware | 2025-09-05 | 7.2 High |
A leftover debug code vulnerability exists in the cli_server debug functionality of Tp-Link ER7206 Omada Gigabit VPN Router 1.4.1 Build 20240117 Rel.57421. A specially crafted series of network requests can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability. | ||||
CVE-2024-30219 | 1 Planex | 4 Mzk-mf300hp2, Mzk-mf300hp2 Firmware, Mzk-mf300n and 1 more | 2025-08-28 | 6.8 Medium |
Active debug code vulnerability exists in PLANEX COMMUNICATIONS wireless LAN routers. If a logged-in user who knows how to use the debug function accesses the device's management page, an unintended operation may be performed. Note that MZK-MF300N is no longer supported, therefore the update for this product is not provided. | ||||
CVE-2025-21472 | 1 Qualcomm | 25 Fastconnect 6900, Fastconnect 6900 Firmware, Fastconnect 7800 and 22 more | 2025-08-18 | 5.5 Medium |
Information disclosure while capturing logs as eSE debug messages are logged. | ||||
CVE-2024-53648 | 2025-08-12 | 6.8 Medium | ||
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device. | ||||
CVE-2024-32047 | 1 Cyberpower | 2 Powerpanel, Powerpanel Business | 2025-07-30 | 9.8 Critical |
Hard-coded credentials for the CyberPower PowerPanel test server can be found in the production code. This might result in an attacker gaining access to the testing or production server. | ||||
CVE-2025-7705 | 2025-07-22 | 6.8 Medium | ||
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions. | ||||
CVE-2025-1479 | 2025-06-03 | 5.3 Medium | ||
An open debug interface was reported in the Legion Space software included on certain Legion devices that could allow a local attacker to execute arbitrary code. | ||||
CVE-2025-46674 | 1 Nasa | 1 Cryptolib | 2025-05-29 | 3.5 Low |
NASA CryptoLib before 1.3.2 uses Extended Procedures that are a Work in Progress (not intended for use during flight), potentially leading to a keystream oracle. | ||||
CVE-2024-29511 | 1 Artifex | 1 Ghostscript | 2025-04-28 | 7.5 High |
Artifex Ghostscript before 10.03.1, when Tesseract is used for OCR, has a directory traversal issue that allows arbitrary file reading (and writing of error messages to arbitrary files) via OCRLanguage. For example, exploitation can use debug_file /tmp/out and user_patterns_file /etc/passwd. | ||||
CVE-2022-46156 | 1 Grafana | 1 Synthetic Monitoring Agent | 2025-04-23 | 7.2 High |
The Synthetic Monitoring Agent for Grafana's Synthetic Monitoring application provides probe functionality and executes network checks for monitoring remote targets. Users running the Synthetic Monitoring agent prior to version 0.12.0 in their local network are impacted. The authentication token used to communicate with the Synthetic Monitoring API is exposed through a debugging endpoint. This token can be used to retrieve the Synthetic Monitoring checks created by the user and assigned to the agent identified with that token. The Synthetic Monitoring API will reject connections from already-connected agents, so access to the token does not guarantee access to the checks. Version 0.12.0 contains a fix. Users are advised to rotate the agent tokens. After upgrading to version v0.12.0 or later, it's recommended that users of distribution packages review the configuration stored in `/etc/synthetic-monitoring/synthetic-monitoring-agent.conf`, specifically the `API_TOKEN` variable which has been renamed to `SM_AGENT_API_TOKEN`. As a workaround for previous versions, it's recommended that users review the agent settings and set the HTTP listening address in a manner that limits the exposure, for example, localhost or a non-routed network, by using the command line parameter `-listen-address`, e.g. `-listen-address localhost:4050`. | ||||
CVE-2017-5259 | 1 Cambiumnetworks | 10 Cnpilot E400, Cnpilot E400 Firmware, Cnpilot E410 and 7 more | 2025-04-20 | N/A |
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://<device-ip-or-hostname>/adm/syscmd.asp. | ||||
CVE-2025-2919 | 1 Netis-systems | 2 Netis Wf-2404, Netis Wf-2404 Firmware | 2025-04-17 | 6.8 Medium |
A vulnerability was found in Netis WF-2404 1.1.124EN. It has been declared as critical. This vulnerability affects unknown code of the component UART. The manipulation leads to hardware allows activation of test or debug logic at runtime. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2020-25156 | 1 Bbraun | 2 Datamodule Compactplus, Spacecom | 2025-04-16 | 7.2 High |
Active debug code in the B. Braun Melsungen AG SpaceCom Version L8/U61, and the Data module compactplus Versions A10 and A11 and earlier enables attackers in possession of cryptographic material to access the device as root. | ||||
CVE-2022-38453 | 1 Contechealth | 2 Cms8000, Cms8000 Firmware | 2025-04-16 | 3 Low |
Multiple binary application files on the CMS8000 device are compiled with 'not stripped' and 'debug_info' compilation settings. These compiler settings greatly decrease the level of effort for a threat actor to reverse engineer sensitive code and identify additional vulnerabilities. | ||||
CVE-2021-40419 | 1 Reolink | 2 Rlc-410w, Rlc-410w Firmware | 2025-04-15 | 7.5 High |
A firmware update vulnerability exists in the 'factory' binary of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted series of network requests can lead to arbitrary firmware update. An attacker can send a sequence of requests to trigger this vulnerability. |