Filtered by vendor Siemens Subscriptions
Total 1936 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-45092 1 Siemens 1 Sinec Ins 2025-05-27 9.9 Critical
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component.
CVE-2023-46285 1 Siemens 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more 2025-05-24 7.5 High
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
CVE-2012-4691 1 Siemens 1 Automation License Manager 2025-05-23 N/A
Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets.
CVE-2012-3040 1 Siemens 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more 2025-05-23 N/A
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
CVE-2012-3037 1 Siemens 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more 2025-05-23 N/A
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
CVE-2021-37198 1 Siemens 1 Comos 2025-05-22 8.8 High
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS uses a flawed implementation of CSRF prevention. An attacker could exploit this vulnerability to perform cross-site request forgery attacks.
CVE-2023-51438 2 Microchip, Siemens 4 Maxview Storage Manager, Simatic Ipc1047e, Simatic Ipc647e and 1 more 2025-05-22 10 Critical
A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access.
CVE-2022-36323 1 Siemens 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more 2025-05-20 9.1 Critical
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
CVE-2022-41851 1 Siemens 2 Jt Open Toolkit, Simcenter Femap 2025-05-20 7.8 High
A vulnerability has been identified in JTTK (All versions < V11.1.1.0), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The JTTK library is vulnerable to an uninitialized pointer reference vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-16973)
CVE-2021-40438 11 Apache, Broadcom, Debian and 8 more 45 Http Server, Brocade Fabric Operating System Firmware, Debian Linux and 42 more 2025-05-16 9 Critical
A crafted request uri-path can cause mod_proxy to forward the request to an origin server choosen by the remote user. This issue affects Apache HTTP Server 2.4.48 and earlier.
CVE-2024-44087 1 Siemens 1 Automation License Manager 2025-05-13 8.6 High
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification.
CVE-2021-31895 1 Siemens 104 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 101 more 2025-05-13 8.1 High
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100PNC (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution.
CVE-2022-38371 1 Siemens 39 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 36 more 2025-05-13 7.5 High
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC00-U (All versions >= V2.3 < V6.30.37), Desigo PXC001-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC100-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC12-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC128-U (All versions >= V2.3 < V6.30.37), Desigo PXC200-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC50-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC64-U (All versions >= V2.3 < V6.30.37), Desigo PXM20-E (All versions >= V2.3 < V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.
CVE-2024-24924 1 Siemens 1 Simcenter Femap 2025-05-09 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2306.0000). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22059)
CVE-2024-24923 1 Siemens 1 Simcenter Femap 2025-05-09 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000), Simcenter Femap (All versions < V2306.0001). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted Catia MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22055)
CVE-2024-23816 1 Siemens 1 Location Intelligence 2025-05-09 9.8 Critical
A vulnerability has been identified in Location Intelligence Perpetual Large (9DE5110-8CA13-1AX0) (All versions < V4.3), Location Intelligence Perpetual Medium (9DE5110-8CA12-1AX0) (All versions < V4.3), Location Intelligence Perpetual Non-Prod (9DE5110-8CA10-1AX0) (All versions < V4.3), Location Intelligence Perpetual Small (9DE5110-8CA11-1AX0) (All versions < V4.3), Location Intelligence SUS Large (9DE5110-8CA13-1BX0) (All versions < V4.3), Location Intelligence SUS Medium (9DE5110-8CA12-1BX0) (All versions < V4.3), Location Intelligence SUS Non-Prod (9DE5110-8CA10-1BX0) (All versions < V4.3), Location Intelligence SUS Small (9DE5110-8CA11-1BX0) (All versions < V4.3). Affected products use a hard-coded secret value for the computation of a Keyed-Hash Message Authentication Code. This could allow an unauthenticated remote attacker to gain full administrative access to the application.
CVE-2024-23813 1 Siemens 1 Polarion Alm 2025-05-09 7.3 High
A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
CVE-2024-23810 1 Siemens 1 Sinec Nms 2025-05-09 8.8 High
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application is vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.
CVE-2024-23803 1 Siemens 1 Tecnomatix Plant Simulation 2025-05-09 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.
CVE-2024-23802 1 Siemens 1 Tecnomatix Plant Simulation 2025-05-09 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.